  "vocabulary": "agritrace.capabilities",
  "version": "1.4.0",
  "notes": "Canonical measurement vocabulary. Drivers MUST convert vendor units to the canonical unit below. New entries are additive only; an id is never reused with a different meaning. Vendor-specific measurements use the 'x-<vendor>.' prefix until promoted into this file. 'meta' (optional) declares checked keys of a reading's meta: each is optional, a key it does not declare stays free-form, and a declared key with a wrong type or out of range makes the reading invalid. 'unitAliases' lists earlier spellings of the canonical unit that are still accepted, so data sent under an earlier version stays valid. 'history' records what an earlier version of this file said (the EPCIS type or the unit) and until which version.",
  "changes": {
    "1.4.0": "Irrigation controller outputs (#242), additive: valve.state (a zone valve, open or closed; the zone in meta.zone), pump.state (the pump, on or off), light.level (a grow light's output level, 0-100 %), water.volume_delivered (litres a zone run delivered, the zone in meta.zone) and dose.volume (litres a dosing pump delivered in a run). The volumes are in litres, as the controller's commands are (max_volume_l) and as apply.product_volume is; a dosing pump's millilitres are written as a decimal of a litre, so there is one volume unit for product and delivered water. water.volume stays the cubic-metre meter total.",
    "1.3.0": "Application records (#241), additive: apply.input (water, fertiliser, pesticide, lime or light), apply.product (the product's id, with its batch and name when known), apply.product_mass and apply.product_volume (how much product), apply.duration (how long, e.g. an irrigation run or the light left on) and apply.phi_days (the pre-harvest interval the product's label gives, in whole days), the readings of an 'apply' event (event types 1.3.0). Irrigation volume, flow, line pressure, fertigation EC and water pH are the existing water.volume, water.flow_rate, water.pressure, water.ec and water.ph. apply.duration is at most one day: a longer application is recorded as several. apply.phi_days is at most 365, a bound on what a record may say, not a value from any label or rule.",
    "1.2.0": "Gateway status heartbeat (#24), additive: gateway.outbox_depth, gateway.dead_letter_count, gateway.link and gateway.peripherals_ready, the readings of the status envelopes a gateway sends about itself under the profile vn.agritrace.gateway (profiles/gateway.json). gateway.peripherals_ready is the first array capability.",
    "1.1.0": "geo.position: checked location-quality keys in meta (acc_m, fix, sats, hdop, age_s, constellations, cn0_mean, cn0_sd, spoof_flag, jam_flag, mock, osnma), all optional (#226). air.humidity: EPCIS type gs1:RelativeHumidity (1.0.0 said gs1:Humidity, which is not a GS1 measurement type); exports made from 1.1.0 on use the new type, and public documents issued before keep the type they were issued with. soil.ph: canonical unit [pH] (UCUM); the 1.0.0 spelling pH is still accepted. Field-sensor capabilities (#231), additive: weather (air.pressure, air.co2, air.vpd, air.dew_point, wind.speed, wind.gust, wind.direction, rain.amount, rain.rate, leaf.wetness), light (light.irradiance, light.ppfd, light.illuminance, light.uv_index), soil (soil.ec_bulk, soil.ec_pore, soil.salinity, soil.water_potential, soil.orp), water (water.flow_rate, water.volume, water.pressure, water.level, water.ec, water.ph, water.do, water.turbidity, water.temperature), plant (plant.sap_flow, plant.sap_velocity, plant.stem_diameter_change, plant.fruit_diameter, plant.canopy_temperature), pests (pest.trap_count), energy (energy.active, power.active) and device health (device.solar_voltage, device.tamper, device.motion). device.tamper and device.motion are the first boolean capabilities. The depth of a soil reading goes in meta.depth_cm. There is no soil nitrogen, phosphorus or potassium capability; NDVI stays an x- capability. Their EPCIS type, UCUM unit and UN/ECE Rec 20 code are listed in capabilities-export-v1.json. No two capabilities share an EPCIS type, because exports carry only type, value and unit: a new capability whose GS1 measurement type another capability already uses has its own CropPath type, and the GS1 type it may adopt later (with a history entry) is the proposed type in capabilities-export-v1.json.",
    "1.0.0": "First version."
  },
  "capabilities": {
    "air.temperature": {
      "valueType": "number", "unit": "Cel", "uom": "CEL",
      "epcisType": "gs1:Temperature", "min": -40, "max": 85
    },
    "air.humidity": {
      "valueType": "number", "unit": "%", "uom": "P1",
      "epcisType": "gs1:RelativeHumidity", "min": 0, "max": 100,
      "history": [{"until": "1.0.0", "epcisType": "gs1:Humidity"}]
    },
    "soil.moisture": {
      "valueType": "number", "unit": "%", "uom": "P1",
      "epcisType": "https://agritrace.vn/voc/SoilMoisture", "min": 0, "max": 100
    },
    "soil.temperature": {
      "valueType": "number", "unit": "Cel", "uom": "CEL",
      "epcisType": "https://agritrace.vn/voc/SoilTemperature", "min": -20, "max": 80
    },
    "soil.ph": {
      "valueType": "number", "unit": "[pH]", "uom": "C62",
      "epcisType": "https://agritrace.vn/voc/SoilPH", "min": 0, "max": 14,
      "unitAliases": ["pH"],
      "history": [{"until": "1.0.0", "unit": "pH"}]
    },
    "mass.net": {
      "valueType": "number", "unit": "kg", "uom": "KGM",
      "epcisType": "https://agritrace.vn/voc/NetMass", "min": 0
    },
    "produce.maturity_index": {
      "valueType": "number", "unit": "%", "uom": "P1",
      "epcisType": "https://agritrace.vn/voc/MaturityIndex", "min": 0, "max": 100
    },
    "produce.maturity_class": {
      "valueType": "enum",
      "enum": ["immature", "mature", "overripe", "defect", "unknown"],
      "epcisType": "https://agritrace.vn/voc/MaturityClass"
    },
    "inference.confidence": {
      "valueType": "number", "unit": "1", "uom": "C62",
      "epcisType": "https://agritrace.vn/voc/InferenceConfidence", "min": 0, "max": 1
    },
    "geo.position": {
      "valueType": "object",
      "required": ["lat", "lon"],
      "properties": {
        "lat": {"valueType": "number", "min": -90, "max": 90},
        "lon": {"valueType": "number", "min": -180, "max": 180}
      },
      "additionalProperties": false,
      "invalidValues": [{"lat": 0, "lon": 0}],
      "epcisType": "https://agritrace.vn/voc/GeoPosition",
      "meta": {
        "properties": {
          "acc_m": {"valueType": "number", "unit": "m", "min": 0, "max": 10000, "description": "Horizontal accuracy in metres as the receiver or phone reports it (68 % confidence radius). HDOP is not an accuracy."},
          "fix": {"valueType": "enum", "enum": ["2d", "3d", "dgnss", "rtk_float", "rtk_fixed"], "description": "Fix type. With no fix the reading is left out, never sent with an old position."},
          "sats": {"valueType": "integer", "min": 0, "max": 255, "description": "Satellites used in the fix."},
          "hdop": {"valueType": "number", "min": 0, "max": 100, "description": "Horizontal dilution of precision (no unit)."},
          "age_s": {"valueType": "number", "unit": "s", "min": 0, "description": "Age of the fix at the reading's time, in seconds."},
          "constellations": {"valueType": "array", "items": {"valueType": "enum", "enum": ["gps", "galileo", "glonass", "beidou", "qzss", "navic", "sbas"]}, "minItems": 1, "uniqueItems": true, "description": "Satellite systems used in the fix."},
          "cn0_mean": {"valueType": "number", "unit": "dB-Hz", "min": 0, "max": 100, "description": "Mean carrier-to-noise density (signal strength) of the satellites used."},
          "cn0_sd": {"valueType": "number", "unit": "dB-Hz", "min": 0, "max": 100, "description": "Standard deviation of that signal strength. Abnormally uniform strength can point to a fake signal."},
          "spoof_flag": {"valueType": "boolean", "description": "The receiver reports a spoofing indication for this fix."},
          "jam_flag": {"valueType": "boolean", "description": "The receiver reports jamming for this fix."},
          "mock": {"valueType": "boolean", "description": "The phone marked the location as coming from a mock location provider."},
          "osnma": {"valueType": "enum", "enum": ["authenticated", "partial", "none", "unsupported"], "description": "Galileo OSNMA status of the fix as the device's own firmware reports it (not an independent source): authenticated, partial (only some satellites or data authenticated), none (supported but not authenticated), unsupported (the receiver has no OSNMA)."}
        },
        "additionalProperties": true
      }
    },
    "device.battery": {
      "valueType": "number", "unit": "%", "uom": "P1",
      "epcisType": "https://agritrace.vn/voc/Battery", "min": 0, "max": 100
    },
    "device.battery_voltage": {
      "valueType": "number", "unit": "V", "uom": "VLT",
      "epcisType": "https://agritrace.vn/voc/BatteryVoltage", "min": 0, "max": 60
    },
    "produce.ripeness_level": {
      "valueType": "integer", "unit": "1", "uom": "C62",
      "epcisType": "https://agritrace.vn/voc/RipenessLevel", "min": 1, "max": 4,
      "description": "Device-measured ripeness level: 1 immature (non), 2 mature-firm (gia), 3 just ripe (chin toi), 4 overripe (chin ruc)."
    },
    "produce.ripeness_level_sensory": {
      "valueType": "integer", "unit": "1", "uom": "C62",
      "epcisType": "https://agritrace.vn/voc/RipenessLevelSensory", "min": 1, "max": 4,
      "requiredMeta": {"source": "operator"},
      "description": "Sensory override of produce.ripeness_level entered by an operator (meta.source = \"operator\"); same 1..4 scale. Demotes the fruit record to self-declared."
    },
    "pack.carton": {
      "valueType": "object",
      "required": ["carton", "fruits", "net_mass_kg"],
      "properties": {
        "carton": {"valueType": "string"},
        "fruits": {"valueType": "array", "items": {"valueType": "string"}, "minItems": 1, "maxItems": 32, "uniqueItems": true},
        "net_mass_kg": {"valueType": "number", "min": 0, "max": 1000}
      },
      "additionalProperties": false,
      "epcisType": "https://agritrace.vn/voc/PackedCarton",
      "description": "One carton as the packing station closed it (#136): its code, the codes of the fruits it holds (1 to 32, each once) and its weighed net mass in kg. A pack event carries one reading per carton."
    },
    "air.pressure": {
      "valueType": "number", "unit": "hPa", "uom": "A97",
      "epcisType": "gs1:Pressure", "min": 300, "max": 1100,
      "description": "Barometric (station) pressure."
    },
    "air.co2": {
      "valueType": "number", "unit": "[ppm]", "uom": "59",
      "epcisType": "gs1:Dimensionless", "min": 0, "max": 40000,
      "description": "CO2 mole fraction in air, in parts per million."
    },
    "air.vpd": {
      "valueType": "number", "unit": "kPa", "uom": "KPA",
      "epcisType": "https://agritrace.vn/voc/VPD", "min": 0, "max": 10,
      "description": "Vapour pressure deficit of the air. Often derived from air temperature and humidity (FAO-56)."
    },
    "air.dew_point": {
      "valueType": "number", "unit": "Cel", "uom": "CEL",
      "epcisType": "https://agritrace.vn/voc/DewPoint", "min": -60, "max": 60
    },
    "wind.speed": {
      "valueType": "number", "unit": "m/s", "uom": "MTS",
      "epcisType": "gs1:Speed", "min": 0, "max": 100,
      "description": "Mean wind speed over the reading's interval."
    },
    "wind.gust": {
      "valueType": "number", "unit": "m/s", "uom": "MTS",
      "epcisType": "https://agritrace.vn/voc/WindGust", "min": 0, "max": 100,
      "description": "Highest wind speed within the reading's interval."
    },
    "wind.direction": {
      "valueType": "number", "unit": "deg", "uom": "DD",
      "epcisType": "gs1:Angle", "min": 0, "max": 360,
      "description": "Direction the wind blows from, in degrees clockwise from true north."
    },
    "rain.amount": {
      "valueType": "number", "unit": "mm", "uom": "MMT",
      "epcisType": "gs1:Length", "min": 0, "max": 1000,
      "description": "Rain fallen during the reading's interval."
    },
    "rain.rate": {
      "valueType": "number", "unit": "mm/h", "uom": "H67",
      "epcisType": "https://agritrace.vn/voc/RainRate", "min": 0, "max": 2000,
      "description": "Rain intensity."
    },
    "leaf.wetness": {
      "valueType": "number", "unit": "%", "uom": "P1",
      "epcisType": "https://agritrace.vn/voc/LeafWetness", "min": 0, "max": 100,
      "description": "Wetness of a leaf-wetness sensor's surface: 0 dry, 100 fully wet."
    },
    "light.irradiance": {
      "valueType": "number", "unit": "W/m2", "uom": "D54",
      "epcisType": "gs1:Irradiance", "min": 0, "max": 2000,
      "description": "Global solar irradiance (pyranometer)."
    },
    "light.ppfd": {
      "valueType": "number", "unit": "umol/m2/s",
      "epcisType": "https://agritrace.vn/voc/PPFD", "min": 0, "max": 3000,
      "description": "Photosynthetic photon flux density (400-700 nm). No UN/ECE Rec 20 code: EPCIS reports carry no uom and, until export v2 (#238), no unit at all (research 5.4 proposes an agri:ucum attribute for that case)."
    },
    "light.illuminance": {
      "valueType": "number", "unit": "lx", "uom": "LUX",
      "epcisType": "gs1:Illuminance", "min": 0, "max": 200000,
      "description": "Illuminance as the human eye sees it; use light.ppfd for plants."
    },
    "light.uv_index": {
      "valueType": "number", "unit": "1", "uom": "C62",
      "epcisType": "https://agritrace.vn/voc/UVIndex", "min": 0, "max": 20,
      "description": "UV index (no unit)."
    },
    "soil.ec_bulk": {
      "valueType": "number", "unit": "mS/cm", "uom": "H61",
      "epcisType": "gs1:Conductivity", "min": 0, "max": 30,
      "description": "Bulk electrical conductivity of the soil around the probe (depends on soil moisture). Not the same as soil.ec_pore. Depth in meta.depth_cm."
    },
    "soil.ec_pore": {
      "valueType": "number", "unit": "mS/cm", "uom": "H61",
      "epcisType": "https://agritrace.vn/voc/SoilECPore", "min": 0, "max": 100,
      "description": "Electrical conductivity of the soil's pore water (as the probe computes it from bulk EC and permittivity). Not the same as soil.ec_bulk. Depth in meta.depth_cm."
    },
    "soil.salinity": {
      "valueType": "number", "unit": "g/L", "uom": "GL",
      "epcisType": "https://agritrace.vn/voc/SoilSalinity", "min": 0, "max": 300,
      "description": "Salt content as the probe reports it, in grams per litre. Depth in meta.depth_cm."
    },
    "soil.water_potential": {
      "valueType": "number", "unit": "kPa", "uom": "KPA",
      "epcisType": "https://agritrace.vn/voc/SoilWaterPotential", "min": -100000, "max": 100,
      "description": "Soil water (matric) potential: negative, more negative is drier. A driver of a sensor that reports tension as a positive number negates it. Depth in meta.depth_cm."
    },
    "soil.orp": {
      "valueType": "number", "unit": "mV", "uom": "2Z",
      "epcisType": "gs1:Voltage", "min": -2000, "max": 2000,
      "description": "Oxidation-reduction potential. Depth in meta.depth_cm."
    },
    "water.flow_rate": {
      "valueType": "number", "unit": "m3/h", "uom": "MQH",
      "epcisType": "gs1:VolumeFlowRate", "min": 0
    },
    "water.volume": {
      "valueType": "number", "unit": "m3", "uom": "MTQ",
      "epcisType": "gs1:Volume", "min": 0,
      "description": "Volume of water; the device profile says whether it is a meter's running total or the volume of the reading's interval."
    },
    "water.pressure": {
      "valueType": "number", "unit": "kPa", "uom": "KPA",
      "epcisType": "https://agritrace.vn/voc/WaterPressure", "min": -100, "max": 2500,
      "description": "Water line pressure (gauge)."
    },
    "water.level": {
      "valueType": "number", "unit": "m", "uom": "MTR",
      "epcisType": "https://agritrace.vn/voc/WaterLevel",
      "description": "Water level of a tank, pond or well against the datum the device's placement records."
    },
    "water.ec": {
      "valueType": "number", "unit": "mS/cm", "uom": "H61",
      "epcisType": "https://agritrace.vn/voc/WaterEC", "min": 0, "max": 200,
      "description": "Electrical conductivity of water (source, tank or drain water)."
    },
    "water.ph": {
      "valueType": "number", "unit": "[pH]", "uom": "C62",
      "epcisType": "https://agritrace.vn/voc/WaterPH", "min": 0, "max": 14
    },
    "water.do": {
      "valueType": "number", "unit": "mg/L", "uom": "M1",
      "epcisType": "gs1:MassConcentration", "min": 0, "max": 50,
      "description": "Dissolved oxygen."
    },
    "water.turbidity": {
      "valueType": "number", "unit": "{NTU}", "uom": "NTU",
      "epcisType": "https://agritrace.vn/voc/Turbidity", "min": 0, "max": 10000,
      "description": "Turbidity in nephelometric turbidity units. UCUM has no NTU unit, so the unit is the UCUM annotation {NTU}."
    },
    "water.temperature": {
      "valueType": "number", "unit": "Cel", "uom": "CEL",
      "epcisType": "https://agritrace.vn/voc/WaterTemperature", "min": -10, "max": 60
    },
    "plant.sap_flow": {
      "valueType": "number", "unit": "L/h", "uom": "E32",
      "epcisType": "https://agritrace.vn/voc/SapFlow", "min": -100, "max": 1000,
      "description": "Sap flow through the stem; negative is reverse flow."
    },
    "plant.sap_velocity": {
      "valueType": "number", "unit": "cm/h", "uom": "H49",
      "epcisType": "https://agritrace.vn/voc/SapVelocity", "min": -200, "max": 200,
      "description": "Heat-pulse sap velocity; negative is reverse flow."
    },
    "plant.stem_diameter_change": {
      "valueType": "number", "unit": "mm", "uom": "MMT",
      "epcisType": "https://agritrace.vn/voc/StemDiameterChange", "min": -50, "max": 50,
      "description": "Change of stem or trunk diameter (dendrometer) against the device's reference."
    },
    "plant.fruit_diameter": {
      "valueType": "number", "unit": "mm", "uom": "MMT",
      "epcisType": "https://agritrace.vn/voc/FruitDiameter", "min": 0, "max": 1000
    },
    "plant.canopy_temperature": {
      "valueType": "number", "unit": "Cel", "uom": "CEL",
      "epcisType": "https://agritrace.vn/voc/CanopyTemperature", "min": -40, "max": 85,
      "description": "Leaf or canopy surface temperature (infrared)."
    },
    "pest.trap_count": {
      "valueType": "integer", "unit": "1", "uom": "C62",
      "epcisType": "gs1:Count", "min": 0,
      "description": "Insects counted in a trap since it was last cleared, as the trap reports it."
    },
    "energy.active": {
      "valueType": "number", "unit": "kW.h", "uom": "KWH",
      "epcisType": "gs1:Energy", "min": 0,
      "description": "Active energy as an energy meter's running total."
    },
    "power.active": {
      "valueType": "number", "unit": "W", "uom": "WTT",
      "epcisType": "gs1:Power",
      "description": "Active power; negative is power fed back."
    },
    "device.solar_voltage": {
      "valueType": "number", "unit": "V", "uom": "VLT",
      "epcisType": "https://agritrace.vn/voc/SolarVoltage", "min": 0, "max": 60,
      "description": "Voltage of the device's solar panel."
    },
    "device.tamper": {
      "valueType": "boolean",
      "epcisType": "https://agritrace.vn/voc/Tamper",
      "description": "The enclosure's tamper switch is open (true) or closed (false)."
    },
    "device.motion": {
      "valueType": "boolean",
      "epcisType": "https://agritrace.vn/voc/Motion",
      "description": "The device's motion sensor or accelerometer detected movement in the reading's interval."
    },
    "gateway.outbox_depth": {
      "valueType": "integer", "unit": "1", "uom": "C62",
      "epcisType": "https://agritrace.vn/voc/GatewayOutboxDepth", "min": 0,
      "description": "Messages waiting in the gateway's store-and-forward queue when it sent its status heartbeat."
    },
    "gateway.dead_letter_count": {
      "valueType": "integer", "unit": "1", "uom": "C62",
      "epcisType": "https://agritrace.vn/voc/GatewayDeadLetterCount", "min": 0,
      "description": "Messages the server refused for good that the gateway keeps for inspection (its dead letters), when it sent its status heartbeat."
    },
    "gateway.link": {
      "valueType": "object",
      "required": ["state"],
      "properties": {
        "state": {"valueType": "enum", "enum": ["connected", "disconnected", "unknown"]},
        "last_error": {"valueType": "string"}
      },
      "additionalProperties": false,
      "epcisType": "https://agritrace.vn/voc/GatewayLink",
      "description": "The gateway's uplink as it last observed it: connected, disconnected (its last send failed) or unknown (nothing sent or connected yet), with the text of its last uplink error, if any."
    },
    "gateway.peripherals_ready": {
      "valueType": "array",
      "items": {
        "valueType": "object",
        "required": ["device", "ready"],
        "properties": {
          "device": {"valueType": "string"},
          "ready": {"valueType": "boolean"}
        },
        "additionalProperties": false
      },
      "maxItems": 256, "uniqueItems": true,
      "epcisType": "https://agritrace.vn/voc/GatewayPeripheralsReady",
      "description": "Each device the gateway serves, by device id, and whether its driver is ready (true) or not (false). An empty list: the gateway serves no device."
    },
    "apply.input": {
      "valueType": "enum",
      "enum": ["water", "fertiliser", "pesticide", "lime", "light"],
      "epcisType": "https://agritrace.vn/voc/ApplicationInput",
      "description": "What an application record applied to the growing area: water (irrigation), fertiliser (fertigation included), pesticide, lime or light."
    },
    "apply.product": {
      "valueType": "object",
      "required": ["id"],
      "properties": {
        "id": {"valueType": "string"},
        "batch": {"valueType": "string"},
        "name": {"valueType": "string"}
      },
      "additionalProperties": false,
      "epcisType": "https://agritrace.vn/voc/ApplicationProduct",
      "description": "The product applied: its id (a registration number, GTIN or the farm's own product code), and its batch and trade name when known."
    },
    "apply.product_mass": {
      "valueType": "number",
      "unit": "kg",
      "uom": "KGM",
      "epcisType": "https://agritrace.vn/voc/ApplicationProductMass",
      "min": 0,
      "description": "Mass of product applied (a solid product, or a liquid one weighed)."
    },
    "apply.product_volume": {
      "valueType": "number",
      "unit": "L",
      "uom": "LTR",
      "epcisType": "https://agritrace.vn/voc/ApplicationProductVolume",
      "min": 0,
      "description": "Volume of liquid product applied, before any dilution; the water it was mixed or irrigated with is water.volume."
    },
    "apply.duration": {
      "valueType": "number",
      "unit": "s",
      "uom": "SEC",
      "epcisType": "https://agritrace.vn/voc/ApplicationDuration",
      "min": 0,
      "max": 86400,
      "description": "How long the application lasted (an irrigation or fertigation run, the time the light was on), from the event's time. At most one day: a longer application is recorded as several."
    },
    "apply.phi_days": {
      "valueType": "integer",
      "unit": "d",
      "uom": "DAY",
      "epcisType": "https://agritrace.vn/voc/PreHarvestInterval",
      "min": 0,
      "max": 365,
      "description": "The pre-harvest interval the applied product's label gives, in whole days: no harvest of the growing area before it has passed since the application ended. The maximum is a bound on what a record may say, not a value from any label or rule."
    },
    "valve.state": {
      "valueType": "enum",
      "enum": ["open", "closed"],
      "epcisType": "https://agritrace.vn/voc/ValveState",
      "description": "State of a zone valve as the controller reports it: open or closed. The zone is in meta.zone."
    },
    "pump.state": {
      "valueType": "enum",
      "enum": ["on", "off"],
      "epcisType": "https://agritrace.vn/voc/PumpState",
      "description": "State of a pump as the controller reports it: on or off."
    },
    "light.level": {
      "valueType": "number",
      "unit": "%",
      "uom": "P1",
      "epcisType": "https://agritrace.vn/voc/LightLevel",
      "min": 0,
      "max": 100,
      "description": "Output level of a grow light as the controller sets it: 0 off, 100 full output. Not what a sensor measures: that is light.ppfd or light.illuminance."
    },
    "water.volume_delivered": {
      "valueType": "number",
      "unit": "L",
      "uom": "LTR",
      "epcisType": "https://agritrace.vn/voc/WaterVolumeDelivered",
      "min": 0,
      "description": "Water a zone run delivered, in litres, as the controller's flow meter counted it for that run (not a running total: water.volume is the meter's cubic metres). The zone is in meta.zone."
    },
    "dose.volume": {
      "valueType": "number",
      "unit": "L",
      "uom": "LTR",
      "epcisType": "https://agritrace.vn/voc/DoseVolume",
      "min": 0,